* Long service life, aging resistance, corrosion resistance
* Flame retardant performance: V-0, non-flame retardant can be customized
* Color: Red, Gray (customizable)
* Easy installation, no flame required, short power-off construction time
Volsun MVCC Medium Voltage Self Locking Overhead Line Insulation Cover for Bare Conductor is a reliable, easy-to-use protective solution designed to boost safety and performance on medium voltage overhead lines. Made for field crews, maintenance teams, and utility companies, this cover helps prevent accidental contact, reduces flashover risk, and protects conductors during work or temporary outages
The cover fits bare conductors and is engineered with a self-locking design that allows quick installation without tools. Its simple snap-on action secures the cover in place and resists slipping under typical field conditions. The user-friendly assembly saves time during live-line work and reduces the need for complex fittings or extra hardware. Lightweight but strong, the cover is easy to carry and handle during routine inspections and emergency repairs
Constructed from high-quality insulating materials, the MVCC cover provides reliable electrical insulation and physical protection. The material resists ultraviolet rays, ozone, moisture, and common pollutants, maintaining its insulating properties over time. This durability lowers replacement frequency and total lifecycle costs. The surface is smooth and easy to clean, helping crews keep equipment in good condition with minimal upkeep
Volsun’s design focuses on compatibility and flexibility. The MVCC cover adapts to a range of conductor sizes commonly found on medium voltage lines. Its form conforms around the conductor to provide consistent insulation and minimize gaps that could allow arcing. The cover’s profile is carefully shaped to balance insulation performance with aerodynamic considerations, helping reduce wind-related stresses once installed
Safety is central to the MVCC cover’s purpose. By adding a visible, insulated barrier over bare conductors, it reduces the risk of accidental contact by personnel, tools, or equipment. The bright, distinctive coloring increases visibility during day and night work. Clear, straightforward markings on each cover indicate correct orientation and installation guidance, supporting safer and more efficient field operations
For utilities and contractors focused on reliable, repeatable workflow, Volsun MVCC covers deliver predictable performance and easy inventory management. The covers are compact and stackable, taking up minimal space in trucks or storage. They are also compatible with standard attachment practices and can be used alongside other temporary insulation products to create comprehensive protection strategies
The Volsun MVCC Medium Voltage Self Locking Overhead Line Insulation Cover for Bare Conductor is a practical, durable, and user-friendly choice for protecting medium voltage conductors. It helps make live-line work safer, speeds up deployment, and reduces maintenance demands—providing clear benefits for crews and asset managers alike




Item |
Typical Value |
Test Method |
||
Electrical Strength Test |
≥20V/mm |
GB/T 1408.1-2006 |
||
Volume Resistivity |
≥1×1014Ω·cm |
GB/T 1410-2006 |
||
Dielectric Constant |
2~3 |
GB/T 1409-2006 |
||
Shore Hardness |
70±5A |
GB/T 531 |
||
Mechanical Properties Before Heat Ageing |
||||
Tensile Strength |
≥4.0MPa |
GB/T 528 |
||
Elongation at break |
≥200% |
GB/T 528 |
||
After Heat ageing 180℃, 7d |
||||
Tensile Strength Change |
±30% |
GB/T 528 |
||
Elongation Change |
±30% |
GB/T 528 |
||
Low Temperature Elongation -15℃, 2h |
≥20% |
GB/T 2951.4-1997 |
||
Low Temperature Flexibility -50℃, 4h |
No cracks |
UL224-2004 |
||
High Temperature Crack Resistance 155℃, 2h |
No cracks |
GB/T2951.6-1997 |
||
LJ Type Aluminum Strand Applicable Product Selection Table |
||||
Nominal cross-sectional area mm² |
Nominal outside diameter mm |
Specifies the specifications of the insulation bushing mm |
||
16 |
5.10 |
Ф 8 |
||
25 |
6.45 |
Ф 10 |
||
35 |
7.50 |
Ф 10 |
||
50 |
9.00 |
Ф 12 |
||
70 |
10.80 |
Ф 14 |
||
95 |
12.50 |
Ф 16 |
||
120 |
14.25 |
Ф 18 |
||
150 |
15.75 |
Ф 20 |
||
185 |
17.50 |
Ф 22 |
||
240 |
20.00 |
Ф 24 |
||
300 |
22.40 |
Ф 28 |
||
400 |
25.90 |
Ф 32 |
||
500 |
29.12 |
Ф 35 |
||
Voltage Level and Wall Thickness Level Corresponding Table |
||||||||
Votalge Rate |
≤10kV |
≤35kV |
≤110kV |
≤220kV |
||||
Wall Thickness |
2.0±0.3mm |
2.6±0.4mm |
4.0±0.5mm |
6.0±1.0mm |
||||










Trade terms |
FOB, EXW, CIF, DDU, DDP, CFR |
Payment terms |
T/T, L/C, Negotiable |
MOQ |
100M |
Supply capability |
1,000,000 mts per month |
Lead time |
Usually 3-5 working days |
Shipment |
Express, Air, Sea |
Port |
Shanghai, Ningbo, Shenzhen |
Sample availability |
Yes |
Sample time |
Usually 1-3 days |
Packaging |
Normal: Plastic bag & Carton & Pallet Special: Customized packing |